10Hz to
10MHz
0.1º Accuracy
---------------------------------
Precision Phasemeter
Automatic Voltage Ranging
Features Accuracy: 0.1° Resolution: 0.1° Input Voltage Range: 10mV rms to 320V rms Accepts Any Waveform
Automatic Voltage Ranging
Analog Output
Options Rack Mount Kit: Part no. RK-316 permits the installation of the Model
6600 into a standard 19" rack spacing. 001: BCD Output. 002: 1Hz operation. 003: Rear panel BNC connectors for REFERENCE and SIGNAL inputs. Extended 1 Year Warranty: Part No. EW6600.
Related Models Model 6200B
- 0.5º Acc.; 1Hz to 1MHz; 0.1º Resolution
>
Model 6600
- 0.5º Acc.; 10Hz to 10MHz; 0.1º Resolution Model 6610 - 0.05º Acc.;
10Hz to 10MHz; 0.01º Resolution Model 6620A - 0.05º Acc.; GPIB; 10Hz
to 10MHz; 0.01º Resolution
DESCRIPTION
The Model 6600 provides
precision phase measurements with a typical accuracy of 0.1° and 0.1° resolution
over most of the frequency range. It will accept a wide range of input signal
levels from 10mV rms to 320V rms and input waveforms including sine, triangle,
square and pulses. A 4 digit, LED display provides continuous direct readout
of phase angles between 0.0° and 360.0°.
APPLICATIONS
The 6600 is the answer for precision
phase angle measurements. Its superior performance and low price, make it ideally
suited for a broad range of applications which include monitoring servo control
systems, low impedance measurements, adjustment of crystal resonance, testing
and adjustment of filter networks, controlling laser trimming of resistor networks,
measurements in ac power systems, secondary standard and general testing and
measurement.
UNIQUE DESIGN
Two common
factors will affect the accuracy of a phasemeter are distortion and/or broadband
noise present on either or both of the input signals. A unique circuit design
used in the 6600 significantly reduces any effects that may be caused by these
two factors.
Another
problem found in most phasemeters is the inability to respond to very small
phase angles, resulting in fluctuations or inconsistencies in the meter reading
(sometimes referred to as ambiguity). To overcome this problem, the 6600 uses
a design that eliminates any ambiguities that may occur at readings near 0°,
180° and 360°.
STANDARD FEATURES
Provided
are an automatic selection of the input voltage range, front panel indicators
to indicate a too low/high input voltage range, and an analog output for use
with an external meter or strip chart recorder.
SPECIFICATIONS
FREQUENCY RANGE:10Hz to 10MHz (1Hz Optional)
ACCURACY
Sinewave:
Input Volts
(rms)
Frequency Range
Accuracy
10mV to 32mV
1Hz to 10kHz
0.3º
10mV to 100mV
10kHz to 50kHz
50kHz to 10MHz
0.4º
0.8º/100kHz
32mV to 100V
1Hz to 10Hz
10Hz to 10kHz
0.2º
0.1º
100mV to 100V
10kHz to 50kHz
50kHz to 100kHz
100kHz to 10MHz
0.1º
0.4º
0.4º/100kHz
100V to 320V
1Hz to 10Hz
10Hz to 5kHz
0.3º
0.2º
Squarewave: Double the sinewave specification.
INPUT Waveforms: Sine,
triangle, square and >50ns pulse. (The phasemeter is triggered on the positive
going transition of the input waveform. A sinewave on the reference input and
a squarewave on the signal input is allowed). Signal Amplitude: Auto ranging from 0.01V rms to 320V rms. Impedance: 1 Megohm in parallel with a 50pF. Maximum DC Component: ±200 volts.
RESPONSE Time Constant:
>10Hz, less than 500ms; <10Hz, less than 5s. Settling Time: To within specified accuracy, within 1 to 8 seconds, dependent
on input amplitude and frequency (>10Hz).
DRIFT Vs. Time (30
days without CALIBRATE reset): Sinewave:
±0.025° from 20Hz to 100kHz
±0.1° at 10Hz
±0.1° per 100kHz above 100kHz.
Squarewave:
±0.025° from 10Hz to 5kHz
±0.05° to 100kHz
±0.1° per 100kHz above 100kHz. Vs. Temperature (without CALIBRATE reset): ±0.01°/°C, 10Hz to 100kHz; ±0.05°/°C to 1MHz.
±0.05°/°C per MHz above 1MHz.
GENERAL Analog Output:
(for use with an external meter or recorder) 0-3.6 volts dc, 10mV dc/degree
phase; Impedance 50 ohms. Display: 0.5", 7 segment, green LED. Display Range: 0.0° to 360.0°. Resolution: 0.1°. Repeatability: Better than 0.1°. Ambient Temperature Range: 0°C to 50°C. Front Panel Controls: POWER, Reference Waveform, Signal Waveform, CALIBRATE
(0° and 360°), phase adjust (0° and 360°). Terminals (BNC): Front Panel: REFERENCE and SIGNAL inputs.
Rear Panel: Analog Output, optional REFERENCE and SIGNAL inputs. Power Requirements: 90-132V or 198-264V, single phase, 50-400Hz, 40W. Dimensions and Weights: 3.5" (8.9cm) high, 16.5" (41.9cm) wide, 16" (40.6cm)
deep; 15 lbs (6.8kg) net, 18 lbs (8.1kg) shipping. Accessories: 3-terminal line cord; operating manual.
OPTIONS Rack Mount
Kit: Part no. RK-316 permits the installation of the Model 6600 into a standard
19" rack spacing. 001: BCD Output. 002: 1Hz operation. 003: Rear panel BNC connectors for REFERENCE and SIGNAL inputs. Extended 1 Year Warranty: Part No. EW6600.
Specifications
are subject to change without notice.