Home  >  Products  >  Distortion Analyzer

Sign-Up to receive our e-mail newsletter.

Keyword Search


 


5Hz to 1MHz
------------------------------------------
Totally Automatic
------------------------------------------
Distortion Analyzer & AC Voltmeter


Features
Fully Automatic Distortion Measurements
Frequency Range:
5Hz to 1MHz, Auto Nulling
Voltage Range:
100mV rms to 130V rms, Auto Leveling
Measures Distortion Down to 0.005%
Measures AC Voltage:
0.010V rms to 130V rms, 5Hz to 1MHz
Internal Oscillator:
1kHz, <.003% Distortion
“Hands Off” Operation

Options
BCD Output: Provides 13 lines of parallel BCD output, plus 1 MODE output, 3 decimal point outputs and 4 separate 3-state control lines. Compatible with DTL, RTL and TTL logic.
002, dB Readout: Switch selectable. Displays the distortion being measured either in percent (%) or dB, as referenced to the level at the Analyzer INPUT.
Rack Mounting Kit: Part No. RK-316 permits the installation of the Model 6900B into a standard 19" rack spacing.
Extended 1 Year Warranty: Part No. EW6900B.
 

DESCRIPTION
The Krohn-Hite Model 6900B is the first and only fully automatic Distortion Analyzer to provide an easy solution to your distortion and AC voltage measurements over the frequency range from 5Hz to 1MHz.

EASE OF OPERATION
Compare the ease of operation of the 6900B to any other distortion analyzer. The 6900B requires only an input signal. Auto frequency nulling, auto level setting and auto-ranging of the digital meter automatically displays the total harmonic distortion (THD). The 6900B measures THD from typically 3Hz to an unprecedented 1MHz and input levels from 100mV rms to 130V rms. Ultra-low distortion can be measured with a resolution of 0.001%. Measurements can be made in less than 3 seconds from 50Hz to 1MHz.

FILTERS
Three switch-selectable filters are provided. A 400Hz high-pass to reduce the effects of hum, 30kHz and 80kHz low-pass to reduce the effects of high frequency noise. An internal low-pass tracking filter is automatically activated at distortion levels below 0.1%.

AC VOLTMETER
As an ac voltmeter, the 6900B measures rms voltage from typically 3Hz to 1MHz at input levels from 10mV to 130V with an accuracy of 2%. A 3 digit auto-ranging display provides 1mV resolution.

ADDITIONAL FEATURES
The Model 6900B provides a distortion output signal which is the input signal after the fundamental is removed. This distortion signal can be used for additional analysis with an oscilloscope or spectrum analyzer. An analog output provides a dc voltage proportional to the distortion signal. An ultra-low distortion (<.003%) 1kHz sinewave oscillator can be used as a source for checking linearity of components and system distortion characteristics. An optional BCD output is available, making the 6900B very useful in an automatic test system. This fully automatic distortion analyzer is ideal for both precision laboratory measurements and routine production testing. It provides faster error free measurements for the unskilled operator.

SPECIFICATIONS

DISTORTION METER
Fundamental Frequency Range: 5Hz to 1MHz automatically tuned over entire specified input frequency range. An intermittent meter display indicates an “out-of-range” condition.
Input: No presetting required over input level from 100mV rms to 130V rms; Impedance, 110k ohms shunted by 100pF.
Distortion Range: A digital panel meter with auto-ranging displays percentage of total harmonic distortion (THD) to 19.9%.

Measurement (%)

Resolution (%)

.10 to 2.00

.01

2.0 to 19.9

.1

Distortion Measurement Accuracy:

Input Volts/Dist. Levels

Frequency

Specifications

.1 to .25:
>0.01%

10Hz to 50kHz

±15% of reading or 0.01% whichever is greater

5Hz to 100kHz

±15% of reading or 0.02% whichever is greater

100kHz to 500kHz

±15% of reading or 0.1% whichever is greater

500kHz to 1MHz

±25% of reading or 0.5% whichever is greater

.25 to 130: >0.005%

10Hz to 50kHz

±15% of reading or 0.005% whichever is greater

5Hz to 100kHz

±15% of reading or 0.01% whichever is greater

100kHz to 500kHz

±15% of reading or 0.05% whichever is greater

500kHz to 1MHz

±25% of reading or 0.5% whichever is greater

Residual Distortion and Noise:

Input

Frequency

Specification

0.1V to 0.25V

20Hz to 20kHz

<0.02%

5Hz to 1MHz

<0.03%, 5Hz to 50kHz, rising to 0.5% at 1MHz.

0.25V to 130V

20Hz to 20kHz

<0.01%

5Hz to 1MHz

<0.02%, 5Hz to 50kHz, rising to 0.5% at 1MHz.

Settling Time (to 0.1% THD): Typically <3s from 50Hz to 1MHz. Longer at lower frequencies.
Fundamental Rejection: Greater than 10dB below residual THD.
Filters:
   
400Hz High-Pass: –3dB at 400Hz ±10%, 40dB/decade rolloff.
    30kHz Low-Pass: –3dB at 30kHz ±5%, 60dB/decade rolloff.
    80kHz Low-Pass: –3dB at 80kHz ±5%, 60dB/decade rolloff.
Distortion Output (Residual signal after fundamental is nulled):
   
Voltage: 100mV rms/% THD.
    Impedance: <500 ohms.
Analog Output: 100mV dc/% THD.
Impedance: <1k ohms.
Display: 3 digit meter with auto-ranging.

AC VOLTMETER
Frequency Range: 5Hz to 1MHz.
Voltage Range: 0.01V rms to 130V rms.

Voltage Range

Resolution

0.01V to 1V

0.001V

1V to 10V

0.01V

10V to 130V

0.1V

Accuracy: ±2% ±1 digit from 10Hz to 500kHz; ±5% ±1 digit from 5Hz to 1MHz over specified voltage range.
Display: 3 digit meter with auto-ranging.
Input Impedance: 110k ohms shunted by 100pF.

OSCILLATOR OUTPUT
Frequency: 1kHz, fixed.
Output: 5V rms at 3mA max.
Distortion: <0.003%.
Impedance: 600 ohms.

GENERAL
Meter Display: 0.55", 7 segment, green LED.
Controls:
  
Front Panel: Mode switch for selecting either VOLTMETER or DISTORTION operation. Filter switch for
   selecting 400Hz high-pass, 30kHz low-pass or 80kHz low-pass operation. Power switch.
   Rear Panel: Switches for selecting 120/240V ac line operation, or NORMAL/LOW ac line voltage.
Connectors (BNC):
  
Front Panel: Input, 1kHz oscillator output and distortion output.
   Rear Panel: Input, analog output.
Operating Temperature Range: 0°C to 45°C.
Maximum DC Component: 100V.
Isolation to Chassis: 500V dc.
Power Requirements: Switch selectable, 90-110, 108-132, 180-220 or 216-264 volts,
single phase, 50-400Hz, 15 watts.
Dimension and Weights: 3" (8.9cm) high, 16" (42.2cm) wide, 14" (37.5cm) deep; 11 lbs (5.2kg),
shipping, 13 lbs (6.1kg).
Accessories: 3-terminal line cord; operating manual.

OPTIONS
BCD Output: Provides 13 lines of parallel BCD output, plus 1 MODE output, 3 decimal point outputs and 4 separate 3-state control lines. Compatible with DTL, RTL and TTL logic.
002, dB Readout: Switch selectable. Displays the distortion being measured either in percent (%) or dB, as referenced to the level at the Analyzer INPUT.
Rack Mounting Kit: Part No. RK-316 permits the installation of the Model 6900B into a standard 19" rack spacing.
Extended 1 Year Warranty: Part No. EW6900B.

OPTIONAL ACCESSORIES
CAB-025: Cable, BNC, 3ft, Low Noise

Specifications are subject to change without notice.

Copyright © April 21, 2006 Krohn-Hite Corporation. All rights reserved.


15 Jonathan Drive, Unit 4, Brockton, MA  02301-5566 U.S.A.
Tel: (508) 580-1660; Fax: (508) 583-8989; info@krohn-hite.com