Home  >  Products  >  Source/Calibrators  >  Model 523

Sign-Up to receive our e-mail newsletter.

Keyword Search


 


±4ppm Accuracy

------------------------
±1ppm Stability
Digit Resolution
------------------------
DC Voltage/Current
Source/Calibrator


----------------------------------------------------------
EN61010-1, Safety and EN61326-1,EMC
 


Features
DC Voltage and Current
Relative Accuracy (90 days): ±4ppm
Stability: ±1ppm
Resolution: 7œ Digits
Wideband Noise (100kHz): <7”Vrms
Maximum Load Current: 110mA
2 and 4-Wire Output
Auto Zero Offset Calibration (AZOC)
Automated “Covers On Calibration”
Certified to N.I.S.T.
One Year Calibration Cycle
GPIB Interface

Related Models
   Model 521/RA5 - ±20ppm to 100Vdc
   Model 522 - ±20ppm to 100Vdc
> Model 523 - ±4ppm to 100Vdc
   Model PCR100 - 100 ohm Precision Current Resistor


Options

PCR100: Precision 100 ohm current resistor. Used to calibrate the Models 521, 522 and 523 DC Source/Calibrators.
KH-523CAL: Calibration and Test Software Program
CAB005: Cable, 2 conductor shielded balanced line.
CAB018: Cable, multi-stacking double banana plug.
CAB023: Low thermal EMF retractable sheath banana plug patch cord set. These cables minimize thermal errors so accurate low voltage measurements can be made. Each set includes 2 test leads (one black and one red).
CAB024: Low thermal EMF spade lug patch cord for low voltage measurements. These cables minimize thermal errors so accurate low voltage measurements can be made. Each set includes 2 test leads (one black and one red).
RK-314: Rack Mount Kit permits the installation of the Model 523 into a 19” rack spacing.

Certification:
A Certificate of Compliance is issued with each new instrument to certify the calibration traceable to U.S. N.I.S.T. (included).

 


GENERAL DESCRIPTION
The NEW Krohn-Hite Model 523 Precision DC Source is a highly stable and repeatable dc voltage source and dc current source providing N.I.S.T. traceable voltages and currents for use in production, calibration labs, QA and QC departments, design labs, or any place where an accurate voltage and current source is needed.

Using Krohn-Hite’s state-of-the-art reference, the 523 provides accurate and stable voltages from ±10nVdc to ±110.99999Vdc to within ±4ppm for 90 days (±8ppm for 1 year), and precise currents from ±10nA to ±110.99999mA to within ±8ppm for 90 days (±16ppm for 1 year). It is an extremely quiet source with <7”Vrms of noise measured over a 10Hz to 100kHz bandwidth (<2”Vrms 0.1Hz to 10Hz).

The 523 features a user friendly 7œ digit display and a membrane keyboard entry of all settings. Output settings can be modified using a plus/minus delta function, multiply/divide function and curser control keys that allow placing a curser on any digit to increment or decrement its value. Output 2-wire, 4-wire and chassis grounding are accomplished with one keystroke or over the GPIB interface bus. A crowbar function places the output in a safe mode when desired. The 523 output can be set to 0 volts, allowing the output sense to maintain a true 4-wire low impedance zero output. It is also quickly forced to zero before a range change to prevent any "surprise voltages" from appearing.

An AUTO ZERO OFFSET CALIBRATION (AZOC) returns any thermally generated offsets to within specified limits and is accessible via the front panel or over the GPIB interface bus. The unit is designed for a "Covers On Calibration” using the KH523CAL Test and Calibration Software Program (Field Calibration License required). With the KH523CAL program and either an HP3458 or Fluke 8508A Digital Voltmeter, unattended calibrations can be made in approximately 15 minutes.

The 523 provides for the storage of up to 31 output settings that can be recalled at any time. Internal operating temperature, serial number, last calibration date and firmware version can all be called to the display for quick access when needed. Error messages are displayed when incorrect or out-of-range entries are made.

APPLICATIONS
Krohn-Hite's NEW Model 523 is well suited for many applications where an extremely accurate and stable dc voltage or dc current is needed. At a cost much less than most sources in its class, the 523 can be a valuable asset to any company's production line, calibration lab, QA and QC department and design lab.

OUTPUT SPECIFICATIONS
The following specifications are with a constant internal operating temperature equal to 40șC ±1șC. The HP3458A NPLC is set for 100 and AUTO CAL cycle (ACAL) run. The Model 523’s calibration is normally done at a room temperature of 23șC ±1șC. The internal Cal Temp is saved at the time of calibration and can be displayed with the present internal temperature using the [TEMP] key.

The 90 day and 1 year specifications are within 24 hours of a zero CQL (AZOC) cycle,  and a constant internal operating temperature equal to 40șC ±1șC. The zero CAL (AZOC) cycle takes out the effect of internal DC offset drift.

(Specifications apply at an internal temperature of 40șC ±1șC, <70% relative humidity.)

Range Res. Relative Uncertainty
±1șC ( see Note 1 )
Absolute Uncertainty±1șC
from calibration temperature
( see Note 2 )
Stability
±1șC *
90 Days 1 Yr 24 Hours 90 Days 1 Yr 24 Hours

-------------------------------    ±(ppm output + ”V or nA)    ---------------------------

DC Voltage

111.11119mV
1.1111119V
11.111119V
110.99999V

10nV
100nV
1”V
10”V

4 + 2
4 + 3
4 + 20
6 + 200

8 + 2
8 + 3
8 + 20
10 + 200

3 + 2
3 + 2
3 + 10
5 + 100

6 + 2
6 + 3
6 + 20
8 + 200

10 + 2
10 + 3
10 + 20
12 + 200

1 + 1
1 + 1
1 + 10
1 + 100

DC Current

11.111119mA
110.99999mA **

1nA
10nA

8 + 40
8 + 200

16 + 40
16 + 200

4 + 20
+44 to -4, ±400

10 + 40
+50 to -10, ±400

18 + 40
+58 to -18, ±400

2 + 20
2 + 100

* Non-Additive
** For values between 12mA and 110mA use graph provided with PCR100 Precision Current Resistor.


Note 1:
The RELATIVE ACCURACY specifications are to the HP3458A Digital Voltmeter used for calibration.

Note 2:
The absolute accuracies and traceability to N.I.S.T. include the traceability accuracies of the calibration standard and the maintained RELATIVE accuracies of the HP3458A added to the 523 RELATIVE specifications.


Note 3:
Current calibration uses an external precision 100-ohm resistor (Krohn-Hite Model PCR100) and measures the voltage using a 4-wire Kelvin connection to the resistor.

Range Temperature Coefficient Linearity
±1șC
Noise Equivalent
Output Z0
(ohms)
18șC - 28șC 0șC - 40șC 0.1Hz - 10Hz 10Hz - 100kHz
±(ppm output + ”V or nA)/șC p-p rms
DC Voltage
111.11119mV
1.1111119V
11.111119V
110.99999V
1 + 0.2
1 + 0.5
1 + 1
2 + 10
2 + 0.2
2 + 0.5
2 + 1
4 + 10
1 + 1
1 + 1
1 + 10
1 + 100
2”V
2”V
4”V
40”V
7”V
7”V
15”V
100”V
0.1”
1”
10”
100”
DC Current
11.111119mA
110.99999mA
2 + 5
2 + 10
4 + 5
4 + 10
1 + 20
1 + 100
20nA
200nA
150nA
300nA
10G
1G
Temperature coefficient is best straight line fit method.

Settling Time: <10ms.
Line Regulation: <±0.1ppm change for a 10% change from normal line voltage, typically no measurable change.
Load Regulation 4-Wire operation: <±0.1ppm change from no load to 100mA full load, typically no measurable change. Measurements must be made at sense lead connection point to the load.
Compliance Voltage Effect On Current Output:
<10nA change for a 100V change in compliance voltage for output currents <11.11112mA, equivalent to >10 Gig-ohm output impedance; <100nA change for a 100V change in compliance voltage for output currents ł11.11112mA, equivalent to >1 Gig-ohm output impedance.
Compliance Voltage Limit: Settable in 1V steps from 1V to 110V. Compliance limits approximately 15% +0.25V above the setting.
Warm-Up Time from a Cold Start: 1 Hour to within 5ppm of final value. 4 Hours to rated accuracy and final value.
Maximum Output Current: ±110mA. Output protected from damage with a current limiter. Output may be shorted to ground indefinitely.
Calibration: The Model 523 is specified with a 1-year calibration cycle. An AUTO ZERO OFFSET CALIBRATION (AZOC) is provided that returns any thermally generated offset to within specified limits, and can be accessed via front panel controls or over the GPIB interface bus. The Model 523 is designed for a “Covers On” calibration using the KH523CAL Test and Calibration Software Program (license required). The KH523CAL software, together with an HP3458A or Fluke 8508A Digital Voltmeter, allows virtually unattended calibration to be performed in approximately 15 minutes. The calibration date and internal temperature is stored in memory and can be called to the display or over the GPIB interface bus.
Calibration Temperature Limits (“Covers-On Calibration”): Internal temperature (T Cal), 40șC ±1șC; Ambient temperature
(T Amb), 0șC to 30șC.

Protection:
Voltage mode, short-circuit and over-load protected. Current mode, open circuit protected. Indication by display message. Automatic recovery.

GPIB PROGRAMMING
Switching Time: Typically 300ms.
Subsets:
SH1, AH1, T6, SR1, RL1, PP1, DC1, DC1, DT1, CO, E1.
Line Termination: The GPIB OEI signal is always sent with the last character on a line.
Talker Function: Allows interrogation of the Model 523 by a controller.

TERMINALS

Output Terminals are mounted on both the front and rear panels. Only one set of terminals may be used at a time. Both terminal sets are configured for remote sensing of the output as follows:

High Output and High Sense
Low Output and Low Sense
Case Ground.

GENERAL
Display: LCD, 7.5 digits. Displays output settings and other pertinent information.
Isolation: Power transformer-to-analog output, control logic-to-analog output, optically isolated.

SAFETY
The Model 523 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control and laboratory use: IEC61010-1, EN61010-1

ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity: EN61326-1, EMC, 61000-4-2;  ESD, 61000-4-3; Radiated Immunity, 61000-4-4;  EFT, 61000-4-5; Surge, 61000-4-6;  Conducted Immunity, 61000-4-8; Magnetic Immunity, 61000-4-11; Voltage Interuption EN61010-1.
CE Compliant for Class B Equipment.

MECHANICAL
Power Requirements:
Selectable 105-130 or 210-260 volts ac, single phase, 50Hz to 60Hz, 60 watts
Dimensions and Weights: 3.5“ (9cm) high, 14" (36cm) wide, 12.5” (32.13cm) deep;
12 lbs (5.4kg) net, 14 lbs (6.3kg) shipping.
Operating Temperature Range: 0șC to 50șC.

OPTIONS
PCR100: 100 Ohm Precision Current Resistor
RK-314: Rack Mount Kit permits the installation of the Model 523 into a 19” rack spacing.
KH523CAL: Calibration and Test License - License to unlock the 523 for calibration with KH523CAL Calibration Software.

CAB005: Cable, 2 conductor shielded balanced line.

CAB018: Cable: multi-stacking double banana plug.

CAB023: The CAB023  is a low thermal EMF retractable sheath banana plug patch cord set. These low thermal cables minimize thermal errors so accurate low voltage measurements can be made. Each set includes 2 test leads (one black and one red).

CAB024: The CAB024  is a low thermal EMF spade lug patch cord set for low voltage measurements. These low thermal cables minimize thermal errors so accurate low voltage measurements can be made. Each set includes 2 test leads (one black and one red).

ACCESSORIES
3 terminal line cord.
Operating manual.

Specifications are subject to change without notice.

Copyright © November 15, 2006 Krohn-Hite Corporation. All rights reserved.


15 Jonathan Drive, Unit 4, Brockton, MA  02301-5566 U.S.A.
Tel: (508) 580-1660; Fax: (508) 583-8989; info@krohn-hite.com