GPIB Remote Controlled
------------------------------
10 Amp AC/DC
------------------------------
Current Calibrator
 


Applications

Direct Calibration of Watt Meters, Meter Shunts, AC and DC Current Meters, I to E transducers, DVMs, DMMs and Relay Coil Current Testing.

Options
Extended 1 Year Warranty: Part No. EWPCS2B.

Related Models
   Model 3210C - 100 Amp AC Current Standard


GENERAL DESCRIPTION
The Model PCS-2/B is a current-to-voltage calibrator or transconductance amplifier. The current output is directly proportional to the input voltages from a high accuracy AC or DC voltage standard. The input voltage to the unit can be AC or DC up to 1kHz.  The ratios of 10 volts to output is: 1:1, 1:0.1, 1:0.01, 1:0.001 and 1:0.0001.  The PCS-2/B is laboratory calibrated with instruments and load resistors traceable to N.I.S.T. (National Institute of Standards & Technology).  The unit is also equipped for rack mounting in a standard 19" rack.

Recommended for DC – Models 511 and 521
Recommended for AC – Models 4601, 4503 or 4032
For watt hour systems see System 4700

The PCS-2B may also be used with AC and DC voltage sources (calibrators) of other manufacturers.

APPLICATIONS
Applications for the Model PCS-2B include: Direct Calibration of Watt Meters, Meter Shunts, AC and DC Current Meters, I to E Transducers, DVMs, DMMs, Relay Coil Current Testing.

SPECIFICATIONS

INPUT
Input Voltage: 0V to ±11Vdc or 0V to 11Vac (rms).
Input Impedance: 10k ohms (all ranges).
AC Bandwidth: 40Hz to 1kHz.

OUTPUT

Ranges

Resolution

Compliance
Voltage

Load
Regulation

Distortion*
(50Hz to 1kHz)

10A

10µA

1.5Vdc or peak ac

±0.015%

<0.5%

1A

1µA

5Vdc or peak ac

±0.015%

<0.1%

100mA

100nA

5Vdc or peak ac

±0.01%

<0.1%

10mA

10nA

5Vdc or peak ac

±0.01%

<0.1%

1mA

1nA

5Vdc or peak ac

±0.01%

<0.1%

* Distortion: Added to the distortion of the AC voltage calibrator.

Accuracy: DC, ±(0.01% of setting + 0.01% of range + 10µA);
AC, ±(0.05% of setting + 0.01% of range + 20µA).
Line Regulation:
±0.0005% for ±10% line change.
Stability: DC, 0.001% of range; AC, 0.005% of range.
Isolation: Floating output; limited only by the isolation of the driving voltage source. Ripple and Noise, rms, non-additive, in a band-pass 0.1Hz to 100kHz: 1mA range, 1.5µA; 10mA range, 3.0µA; 100mA range, 40µA; 1A range, 80µA; 10A range, 375µA.

PROGRAMMING (IEEE-488.1)
The 5 ranges are GPIB programmable as well as controlled locally with front panel controls. A dip-switch, located on the rear panel, is used to set the instruments bus address.

GENERAL
Power Requirements: 117Vac, 60Hz, 150 watts or 220Vac, 50Hz.
Temperature Coefficient: 10A and 1A ranges, 50ppm/°C; 100mA, 10mA and 1mA ranges, 10ppm/°C.
Operating Temperature: –10°C to 40°C.
Dimensions: 5.22" (12.25cm) high, 17" (43.18cm) wide, 15" (38.1cm) deep.
Weight: 30 lbs. (13.6kg) net; 34 lbs. (15.4kg) shipping.
Protection: A front panel lamp indicates when the compliance voltage has exceeded or when a malfunction has occurred.
Certification: Certificate of Compliance traceable to U.S. N.I.S.T.
Warranty: One full year, includes accuracy and stability.
Extended 1 Year Warranty: Part No. EWPCS2B.

OPTIONAL ACCESSORIES
CAB-005:
Cable, Two Conductor Shielded Balance Line
CAB-018:
Cable, Multi-stacking Double Banana plug
CAB-023:
Cable Set, Low Thermal EMF Retractable Banana
CAB-024:
Cable Set, Low Thermal EMF Spade Lug

For a watt-hour meter calibration system see the Model 4700.

Specifications and prices are subject to change without notice.

Copyright © April 21, 2006 Krohn-Hite Corporation. All rights reserved.


15 Jonathan Drive, Unit 4, Brockton, MA  02301-5566 U.S.A.
Tel: (508) 580-1660; Fax: (508) 583-8989; info@krohn-hite.com