DC Voltage Calibrator


Features
High Speed: 50µS switching and settling time
Low Electrical Noise
High Accuracy:
0.002% “Limit of Error” or “Worst Case” Method. The accuracy statement is not degraded with time, drift, temperature, line or load specifications.
Outputs:
±0.1µV to 10V dc with ranging
Protection:
Overload, short-circuit protection, current limited.
High Stability and Repeatability
TTL Logic, BCD Code
Optional Programming Formats:
GPIB, Binary

Options
BCD Format: Use 501/J-1.
Binary Format: Use 501/J-2.
GPIB Cable/Connector Assembly
1-Meter: Part No. 3045-1.
2-Meter: part No. 3045-2.
Binary Format:
Use 501/J-2.
GPIB Cable/Connector Assembly
1-Meter: Part No. 3045-1.
2-Meter: part No. 3045-2.
 


GENERAL DESCRIPTION
The Model 501J Programmable DC Voltage Standard is a versatile reference source, designed to meet the needs of computer systems, production line testing, automated calibration and standards laboratories.

The 501J has a specified accuracy, and are traceable through a bank of saturated standard cells to the U.S. National Institute of Standards & Technologies.  The 501J is a highly accurate reference which can be used for calibration of digital voltmeters, analog meters, semiconductor analyzing systems, analog references for computers, analog-to-digital converters, telemetry and data acquisition systems, and wherever a stable source is required.

The 501J is also equipped with overload and short circuit protection, and is fully operational in normal environmental conditions.  The unit will drive a short circuit indefinitely without damage, and will recover to rated specifications in less than 10ms

SPECIFICATIONS

OUTPUT

Range Full Scale Resolution Current Zo
10V ±10.00000Vdc 10µV 50mA 0.03 ohms
100mV ±100.0000mVdc 0.1µV EMF* into 150k ohm load Constant 3 ohms

* Note: The rated accuracy of the 100mV range applies when the RL is 150k ohms or higher. (see Output Impedance) e.g.. where Zo = 3 ohms and RL = 150k ohms. IR error = 0.002% of programmed value. Remote sensing, 4-terminal, is provided on all ranges 10V and higher.

Accuracy (Relative to N.I.S.T. Standards):
±(0.002% of setting + 0.0005% of range + 3µV). The Accuracy statement is based on the “Limit-of--Error” (or “worst-case”) method. All other specifications noted hereafter, which affect accuracy, e.g.., line, load, temperature, drift changes are included in the accuracy statement. Thus, all other specifications are listed as *NON-ADDITIVE. Specifications guaranteed for 12 months.
Setting Time: 50µS to 0.002% of programmed voltage, including polarity change.
Stability (*non-additive): 24 hrs., ±0.001%; 90 days, ±0.0015%;1 year, ±0.002%.
Ripple and Noise: 0.0005% of range + 2µVrms in a band-pass of 0.1Hz to 100kHz, no random spikes.
Output Current: 10V range, 100mV, EMF into 150k ohm load. Note: The rated accuracy of the 100mV range applies when the RL = 150k ohms or higher. (See Output Impedance) e.g. Where Zo = 3 ohms and RL = 150k ohms. IR error = 0.002% of programmed value.
Remote sensing, 4-terminal, is provided on 10V range.
Output Impedance: 10V range, 0.03 ohms; 100mV range, constant 3 ohms.
Regulation (*non-additive): Line and load, ±0.0005%.
Protection: Short-circuit and overload protection with front panel indicator. Standby/Ready signal to programmer.
Isolation: Power transformer primary to analog output, 25G ohms, 300pF; control logic-to-analog output, with opto-isolators P/N IS-40, 1G ohm 130pF, 500Vdc.
Temperature Coefficient (*non-additive): Ambient, ±0.0005%/°C; operating limit, ±0.001%/°C.

PROGRAMMING FORMAT
The following information applies to the Mainframe Model 501, without options, etc. For additional functions and ranges see the following pages for options, accessories, and auxiliary instruments.
Parallel Entry
   Input Loading Factor: 1 TTL standard load per bit line.
   Logic Swing: Logical “0” = 0.8V (max.) Logical “1” = +2V (min.)
   Code: Binary coded decimal (BCD).
   Logic Lines: 20 lines + strobe + return (parallel entry).
Serial Entry: See accessory KT-488.

MECHANICAL SPECIFICATIONS
Power Requirements: 10 watts, 115V or 230Vac, 50Hz to 60Hz.
Temperature: Calibration, 23°C ±1°C; ambient, 20°C to 30°C; operating limit, 10°C to 50°C; storage, -40°C to 85°C.
Dimensions: 19.1" (485mm) wide, 5.2" (133mm) high, 14.2" (361mm) deep.
Weight: 15.5 lbs. (7.0kg) net; 21 lbs. (9.5kg) shipping.
10 watts, 115V or 230Vac, 50Hz to 60Hz.
Temperature: Calibration, 23°C ±1°C; ambient, 20°C to 30°C; operating limit, 10°C to 50°C; storage, -40°C to 85°C.
Dimensions: 19.1" (485mm) wide, 5.2" (133mm) high, 14.2" (361mm) deep.
Weight: 15.5 lbs. (7.0kg) net; 21 lbs. (9.5kg) shipping.

ACCESSORIES AND OPTIONS
Straight Binary Entry: Order 501/J-2, this is the equivalent to 6 decimal digits or 24 bit resolution.
   Range MSB Full Scale LSB
   10V 5.12V 10.24V 10µV rounded off
   100mV 5.12mV 102.4mV 0.1µV rounded off
Mating Connectors: Supplied with new instruments, field installable.
   Program Input: Part No. MP-0156 (for parallel only).
   Analog Output: Part No. 3106.
Rack Mounting Brackets (with handles): Part No. RK-01, supplied with new instruments.
Memory Register: Part No. MR-1 (for parallel only). This eliminates the requirement to “hold-up” the bit lines in order to sustain the programmed voltage output. The register will only respond to the level command. Thus, the programmer may be used for other functions while the calibrator voltage is maintained. Construction: Plug-in PC board, field installable.
Opto-Isolation:
Part No. IS-40. The opto-isolators provide the maximum isolation between the logic circuit and the analog output 1G ohm, 130pF, 500Vdc. Many applications do not require this high degree of isolation. The opto-isolators are conveniently mounted on a plug-in PC board. Therefore, the opto-isolators may be installed, in the field, when and if the need arises.
GPIB, GPIB Interface: Part No. KT-488 (optional). Opto-isolation is included. Construction: Two plug-in PC boards, field installable.
Extended 1 Year Warranty: Part No. EW501/J1, EW501/J2.

ORDERING INFORMATION
BCD Format: Use 501/J-1.
Binary Format: Use 501/J-2.
GPIB Cable/Connector Assembly
1-Meter: Part No. 3045-1.
2-Meter: part No. 3045-2.

Binary Format: Use 501/J-2.
GPIB Cable/Connector Assembly
1-Meter: Part No. 3045-1.
2-Meter: part No. 3045-2.

Specifications and prices are subject to change without notice.

Copyright © February 23, 2006 Krohn-Hite Corporation. All rights reserved.


15 Jonathan Drive, Unit 4, Brockton, MA  02301-5566 U.S.A.
Tel: (508) 580-1660; Fax: (508) 583-8989; info@krohn-hite.com