APPLICATIONS
Applications for the Model 3200C include direct calibration of watt meters,
meter shunts, AC and DC current meters, I to E transducers, DVMs, DMMs and relay
coil current testing.
GENERAL DESCRIPTION
The Model 3200C is a transconductance amplifier whose current output is directly
proportional to the input voltages from a high accuracy AC or DC voltage standard.
The ratios of 10 volts to output is:
1:1, 1:0.1, 1:0.01,
1:0.001 and 1:0.0001
Recommended for DC – Models 511 and 521
Recommended for AC – Models 4601, 4503 or 4032
For watt hour systems
see System 4700. The 3200C may also be used with
AC and DC voltage sources (calibrators) of other manufacturers.
SPECIFICATIONS
INPUT
Input Voltage:
0V to ±11Vdc or 0V to 11Vac (rms).
Input Impedance: 10k ohms (all ranges).
AC Bandwidth: 40Hz to 1kHz.
OUTPUT
SPECIFICATIONS
|
Ranges |
Resolution |
Compliance Voltage |
Load Regulation |
Distortion*
(50Hz to 1kHz) |
|
10A |
10µA |
1.5Vdc or peak ac |
±0.015% |
<0.5% |
|
1A |
1µA |
5Vdc or peak ac |
±0.015% |
<0.1% |
|
100mA |
100nA |
5Vdc or peak ac |
±0.01% |
<0.1% |
|
10mA |
10nA |
5Vdc or peak ac |
±0.01% |
<0.1% |
|
1mA |
1nA |
5Vdc or peak ac |
±0.01% |
<0.1% |
* Distortion: Added to the distortion
of the AC voltage calibrator.
Accuracy:
DC, ±(0.01% of setting + 0.01% of range + 10µA); AC, ±(0.05% of setting + 0.01%
of range + 20µA).
Line Regulation: ±0.0005% for ±10% line change.
Stability: DC, 0.001% of range; AC, 0.005% of range.
Isolation: Floating output; limited only by the isolation of
the driving voltage source.
Ripple and Noise, rms, non-additive, in a band-pass 0.1Hz to 100kHz:
1mA range, 1.5µA; 10mA range, 3.0µA; 100mA range, 40µA; 1A range, 80µA; 10A
range, 375µA.
GENERAL
Power Requirements:
117Vac, 60Hz, 150 watts or 220Vac, 50Hz.
Temperature Coefficient: 10A and 1A ranges, 50ppm/°C; 100mA,
10mA and 1mA ranges, 10ppm/°C.
Operating Temperature: –10°C to 40°C.
Dimensions: 5.22" (12.25cm) high, 17" (43.18cm) wide, 15" (38.1cm)
deep.
Weight: 30 lbs. (13.6kg) net; 34 lbs. (15.4kg) shipping.
Protection: A front panel lamp indicates when the compliance
voltage has exceeded or when a malfunction has occurred.
Certification: Certificate of Compliance traceable to U.S.
N.I.S.T.
Warranty: One full year, includes accuracy and stability.
OPTIONS
Extended
1 Year Warranty:
Part No. EW3200.
Specifications and
prices are subject to change without notice.
Copyright
© February 23, 2006 Krohn-Hite
Corporation. All rights reserved.
15 Jonathan Drive, Unit 4, Brockton, MA 02301-5566 U.S.A.
Tel: (508) 580-1660; Fax: (508) 583-8989; info@krohn-hite.com